<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	
	>
<channel>
	<title>
	Comments on: Don&#8217;t Epoxy Until You&#8217;ve Done This Simple Moisture Test First	</title>
	<atom:link href="https://allgaragefloors.com/concrete-moisture-test/feed/" rel="self" type="application/rss+xml" />
	<link>https://allgaragefloors.com/concrete-moisture-test/</link>
	<description>Garage flooring products, options, and reviews</description>
	<lastBuildDate>Thu, 03 Aug 2023 20:15:27 +0000</lastBuildDate>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.0.2</generator>
	<item>
		<title>
		By: Shea		</title>
		<link>https://allgaragefloors.com/concrete-moisture-test/comment-page-2/#comment-136728</link>

		<dc:creator><![CDATA[Shea]]></dc:creator>
		<pubDate>Thu, 03 Aug 2023 20:15:27 +0000</pubDate>
		<guid isPermaLink="false">http://allgaragefloors.com/?p=332#comment-136728</guid>

					<description><![CDATA[In reply to &lt;a href=&quot;https://allgaragefloors.com/concrete-moisture-test/comment-page-2/#comment-136723&quot;&gt;ben&lt;/a&gt;.

Hi Ben. OK, we can see why you may have moisture in that room. Also, make sure that water easily and quickly drains away from the area between the house and retaining wall or the slab will soak it up like a sponge. It sounds like the contractor used a pinless moisture meter. The 17% does not help us unless we know in what measurement reference it is related to. However, if it was determined that the readings were sufficient for a moisture blocking epoxy, then the humidity in the room will decrease quite a bit as a result. This is assuming the main source is from the floor and no where else. Humidity in the room cannot build up if moisture is being blocked from entering.]]></description>
			<content:encoded><![CDATA[<p>In reply to <a href="https://allgaragefloors.com/concrete-moisture-test/comment-page-2/#comment-136723">ben</a>.</p>
<p>Hi Ben. OK, we can see why you may have moisture in that room. Also, make sure that water easily and quickly drains away from the area between the house and retaining wall or the slab will soak it up like a sponge. It sounds like the contractor used a pinless moisture meter. The 17% does not help us unless we know in what measurement reference it is related to. However, if it was determined that the readings were sufficient for a moisture blocking epoxy, then the humidity in the room will decrease quite a bit as a result. This is assuming the main source is from the floor and no where else. Humidity in the room cannot build up if moisture is being blocked from entering.</p>
]]></content:encoded>
		
			</item>
		<item>
		<title>
		By: ben		</title>
		<link>https://allgaragefloors.com/concrete-moisture-test/comment-page-2/#comment-136723</link>

		<dc:creator><![CDATA[ben]]></dc:creator>
		<pubDate>Thu, 03 Aug 2023 07:04:59 +0000</pubDate>
		<guid isPermaLink="false">http://allgaragefloors.com/?p=332#comment-136723</guid>

					<description><![CDATA[In reply to &lt;a href=&quot;https://allgaragefloors.com/concrete-moisture-test/comment-page-2/#comment-136715&quot;&gt;Shea&lt;/a&gt;.

Hello,

The slab is not below grade, we are at the bottom of a hill, there is a retaining wall about 1.5 metres away from the house. 
They tested the moisture with a surface probe, no drilling. I am not sure of what the 17% measurement is myself.
The room with the higher than average floor moisture reading seems to be very humid, it has bad ventilation and we live in a tropical climate area. I am just worried with bad ventilation, them installing vapour blocking epoxy on the floor, this might cause humidity build up between the epoxy and engineered timber flooring that will go over the top of the expoxy. My big concern is mold forming.]]></description>
			<content:encoded><![CDATA[<p>In reply to <a href="https://allgaragefloors.com/concrete-moisture-test/comment-page-2/#comment-136715">Shea</a>.</p>
<p>Hello,</p>
<p>The slab is not below grade, we are at the bottom of a hill, there is a retaining wall about 1.5 metres away from the house.<br />
They tested the moisture with a surface probe, no drilling. I am not sure of what the 17% measurement is myself.<br />
The room with the higher than average floor moisture reading seems to be very humid, it has bad ventilation and we live in a tropical climate area. I am just worried with bad ventilation, them installing vapour blocking epoxy on the floor, this might cause humidity build up between the epoxy and engineered timber flooring that will go over the top of the expoxy. My big concern is mold forming.</p>
]]></content:encoded>
		
			</item>
		<item>
		<title>
		By: Shea		</title>
		<link>https://allgaragefloors.com/concrete-moisture-test/comment-page-2/#comment-136715</link>

		<dc:creator><![CDATA[Shea]]></dc:creator>
		<pubDate>Tue, 01 Aug 2023 16:50:10 +0000</pubDate>
		<guid isPermaLink="false">http://allgaragefloors.com/?p=332#comment-136715</guid>

					<description><![CDATA[In reply to &lt;a href=&quot;https://allgaragefloors.com/concrete-moisture-test/comment-page-2/#comment-136714&quot;&gt;ben&lt;/a&gt;.

Hello Ben. Is your slab below grade or up against a hill? The 17% RH reading does not provide enough information for us since we don&#039;t know exactly what type of RH test was performed. Most require drilling a hole in the concrete in various places to place meters. What we can tell you, however, is that moisture vapor blocking epoxy primer coatings do just what they say - block moisture vapor transmission. It will not cause damage to the concrete. This is a common practice in the coating and flooring industry providing that the moisture vapor readings are not too high. We are assuming that the company who recommended this process has already verified that the moisture vapor content does not exceed the parameter of the coating. I&#039;m not sure why you believe that humidity will be trapped inside the room when moisture vapor is being blocked. Can you elaborate?]]></description>
			<content:encoded><![CDATA[<p>In reply to <a href="https://allgaragefloors.com/concrete-moisture-test/comment-page-2/#comment-136714">ben</a>.</p>
<p>Hello Ben. Is your slab below grade or up against a hill? The 17% RH reading does not provide enough information for us since we don&#8217;t know exactly what type of RH test was performed. Most require drilling a hole in the concrete in various places to place meters. What we can tell you, however, is that moisture vapor blocking epoxy primer coatings do just what they say &#8211; block moisture vapor transmission. It will not cause damage to the concrete. This is a common practice in the coating and flooring industry providing that the moisture vapor readings are not too high. We are assuming that the company who recommended this process has already verified that the moisture vapor content does not exceed the parameter of the coating. I&#8217;m not sure why you believe that humidity will be trapped inside the room when moisture vapor is being blocked. Can you elaborate?</p>
]]></content:encoded>
		
			</item>
		<item>
		<title>
		By: ben		</title>
		<link>https://allgaragefloors.com/concrete-moisture-test/comment-page-2/#comment-136714</link>

		<dc:creator><![CDATA[ben]]></dc:creator>
		<pubDate>Tue, 01 Aug 2023 04:24:47 +0000</pubDate>
		<guid isPermaLink="false">http://allgaragefloors.com/?p=332#comment-136714</guid>

					<description><![CDATA[Hello, I am looking for some advice, our rumpus room in our single story home has moisture coming up through the concrete slab, a reading of 17%.
We want to install engineered timber flooring on the slab however we are concerned about the high moisture 
that will most likely cause mold under the timber flooring without any coating on the slab.
We have had a company advise they can apply 3 coats of hydrostatic pressure resistant epoxy coating flooring on top of the concrete slab to stop the moisture coming up.
I am concerned this may damage the slab over time and also concerned humidity will be trapped inside the room and still may cause mold under the timber flooring above the epoxy flooring.
What are your thoughts?]]></description>
			<content:encoded><![CDATA[<p>Hello, I am looking for some advice, our rumpus room in our single story home has moisture coming up through the concrete slab, a reading of 17%.<br />
We want to install engineered timber flooring on the slab however we are concerned about the high moisture<br />
that will most likely cause mold under the timber flooring without any coating on the slab.<br />
We have had a company advise they can apply 3 coats of hydrostatic pressure resistant epoxy coating flooring on top of the concrete slab to stop the moisture coming up.<br />
I am concerned this may damage the slab over time and also concerned humidity will be trapped inside the room and still may cause mold under the timber flooring above the epoxy flooring.<br />
What are your thoughts?</p>
]]></content:encoded>
		
			</item>
		<item>
		<title>
		By: Shea		</title>
		<link>https://allgaragefloors.com/concrete-moisture-test/comment-page-2/#comment-136692</link>

		<dc:creator><![CDATA[Shea]]></dc:creator>
		<pubDate>Fri, 28 Jul 2023 05:11:08 +0000</pubDate>
		<guid isPermaLink="false">http://allgaragefloors.com/?p=332#comment-136692</guid>

					<description><![CDATA[In reply to &lt;a href=&quot;https://allgaragefloors.com/concrete-moisture-test/comment-page-2/#comment-136686&quot;&gt;Tim Springer&lt;/a&gt;.

Hi Tim. Yep, the oily substance is the byproduct of moisture in the concrete mixing with minerals and other ingredients in the concrete. Is your slab below grade or up against a hill or bank? If so, that could explain your moisture issue. Water that does not drain away from the slab or pools against the foundation can cause moisture issues as well. Generally, humidity will not affect the test results. However, if the dome of the test kit was not sealed properly to the concrete it can skew the results. In addition, if water had been introduced to the surface within the previous 48-72 hours, it may not have had time to completely dry throughout the slab and the heat would cause the moisture vapor from within to rise and produce high readings. If any of those two were the case, you may want to test again to see if you get numbers low enough that will qualify for a moisture blocking epoxy primer. 

Garage floor mats are made of polyvinyl and are not breathable. They will block moisture transmission and get wet underneath. If you want a breathable option, we would highly recommend polypropylene (hard plastic) interlocking garage floor tiles. They are breathable and allow for air circulation under the tiles. You can &lt;a href=&quot;https://allgaragefloors.com/interlocking-garage-floor-tile/&quot; title=&quot;What You Should Know About Interlocking Garage Floor Tiles&quot; rel=&quot;ugc&quot;&gt;learn more about them here&lt;/a&gt;.]]></description>
			<content:encoded><![CDATA[<p>In reply to <a href="https://allgaragefloors.com/concrete-moisture-test/comment-page-2/#comment-136686">Tim Springer</a>.</p>
<p>Hi Tim. Yep, the oily substance is the byproduct of moisture in the concrete mixing with minerals and other ingredients in the concrete. Is your slab below grade or up against a hill or bank? If so, that could explain your moisture issue. Water that does not drain away from the slab or pools against the foundation can cause moisture issues as well. Generally, humidity will not affect the test results. However, if the dome of the test kit was not sealed properly to the concrete it can skew the results. In addition, if water had been introduced to the surface within the previous 48-72 hours, it may not have had time to completely dry throughout the slab and the heat would cause the moisture vapor from within to rise and produce high readings. If any of those two were the case, you may want to test again to see if you get numbers low enough that will qualify for a moisture blocking epoxy primer. </p>
<p>Garage floor mats are made of polyvinyl and are not breathable. They will block moisture transmission and get wet underneath. If you want a breathable option, we would highly recommend polypropylene (hard plastic) interlocking garage floor tiles. They are breathable and allow for air circulation under the tiles. You can <a href="https://allgaragefloors.com/interlocking-garage-floor-tile/" title="What You Should Know About Interlocking Garage Floor Tiles" rel="ugc">learn more about them here</a>.</p>
]]></content:encoded>
		
			</item>
		<item>
		<title>
		By: Tim Springer		</title>
		<link>https://allgaragefloors.com/concrete-moisture-test/comment-page-2/#comment-136686</link>

		<dc:creator><![CDATA[Tim Springer]]></dc:creator>
		<pubDate>Thu, 27 Jul 2023 13:05:37 +0000</pubDate>
		<guid isPermaLink="false">http://allgaragefloors.com/?p=332#comment-136686</guid>

					<description><![CDATA[We had our garage floor coated with epoxy like many of our neighbors here in Annapolis MD, but soon afterwards a brown, oily substance began coming up through the floor.  The contractor said our floor probably has moisture coming up &#038; suggested we drill holes in the coating to let it escape.  This accomplished nothing.  We consulted another contractor who suggested removing the coating and performing a moisture test.  We did that and he said he&#039;s never seen test results as high as ours - 22 lbs/1000 sq ft/24 hrs.  He said he cannot apply a coating on our floor &#038; suggested we seal it with a breathable coating which we are unable to find due to such high test results.  We question whether the test was done in proper environment or if that matters.  Our garage was 80-110 F &#038; very humid when the test was conducted over 3 days.  Does that matter?  If the test results are accurate, can we simply install breathable mats over it w/o sealing it?  Thanks for any help!]]></description>
			<content:encoded><![CDATA[<p>We had our garage floor coated with epoxy like many of our neighbors here in Annapolis MD, but soon afterwards a brown, oily substance began coming up through the floor.  The contractor said our floor probably has moisture coming up &amp; suggested we drill holes in the coating to let it escape.  This accomplished nothing.  We consulted another contractor who suggested removing the coating and performing a moisture test.  We did that and he said he&#8217;s never seen test results as high as ours &#8211; 22 lbs/1000 sq ft/24 hrs.  He said he cannot apply a coating on our floor &amp; suggested we seal it with a breathable coating which we are unable to find due to such high test results.  We question whether the test was done in proper environment or if that matters.  Our garage was 80-110 F &amp; very humid when the test was conducted over 3 days.  Does that matter?  If the test results are accurate, can we simply install breathable mats over it w/o sealing it?  Thanks for any help!</p>
]]></content:encoded>
		
			</item>